Application: Vertical Stack Exhaust Rail install for Tanker Truck Use.
Smoke/Dust Type: Diesel Smoke and Fumes
Location: Colorado
Ventilation Equipment Solution Selection: (1) – Plymovent VSR-20 Vertical Stack Exhaust Rail, 20′ length
Plymovent SBT -20 Sliding Balancer Track, 20 ft. length, each includes 500 temperature flex hose, heavy duty retractable balancer, sensors, electrical control panel and pneumatic “Grabber” nozzle.
(1) – Plymovent TEV 559-60 Blower, 5 hp.
CFM/Static Pressure: 2,500 cfm @ 7.5” s.p.
Application Solution: Vertical exhaust stack from tanker truck required an exhaust rail to contain diesel exhaust gases. Sensors located in the VSR exhaust rail start the blower upon engine start up or return to the station making the process completely automatic.
Sliding Balancer Tracks operate with a pneumatic “Grabber” nozzle tailpipe connection that provides a complete seal to the engine tailpipe. Release and re-connection occurs at the station door.
This combined system contains engine exhausts, protects firefighters and day areas while keeping the facility clean.
The upgrade project included 2 additional stations.