Application: Dust generated from fire extinguisher emptying and filling operations.
Dust Type: Sodium Bicarbonate Dust
Location: Colorado
Dust Collection Equipment Solution Selection: (1) – Donaldson/Torit Model DFE 2-8 Continuous Duty Cartridge Filter Dust Collector with TBI-20, 20 h.p. direct Drive Blower and clamping duct system provided airflow to custom slotted back draft hoods at individual workstations. A Donaldson/Torit 1 h x 3 w Auto-Lok Safety After Filter also included.
Donaldson/Torit AirFlow Controller with VFD
Clamping duct system

Airflow/Static Pressure: 6000 cfm @ 14” s.p.
Application Solution: Central dust collection system contained dust production at hoods and reduced overall housekeeping time. Operators were isolated from airborne dust. Energy savings resulted from recycled air.